  • Piping Fabrication and Erection Specification

    PIPE SUPPORTS - Piping Fabrication and Erection Specification All field supports shall be installed in accordance with the standard drawings. If the field supports are not installed or are unavailable when the piping is erected, u s e temporary blocking or other adequate means of support until the field supports can be installed.

    Get Price
  • Engineering Design Guidelines - Recycled Water (Non ...

    2011-2-3u2002·u2002Headloss for pipes less than 16 inches in diameter shall not be greater than 10 ft/1000 ft (4.2 psig per 1000 feet). Headloss for pipes equal to or greater than 16 inches diameter shall not be greater than 5 ft/1000 ft (2.2 psig). The Hazen & Williams formula with the coefficient of friction 'c'= 110 for all pipe

    Get Price
  • SPECIFICATIONS FOR SPIRAL PIPE AND FITTINGS

    2019-4-25u2002·u2002of the spiral pipe and fittings. The installer applies a gasket on one flange, mates the two flanges together, and attaches the barrel clamp. For field cuts a 5/8' flanged sleeve is available. Trim the spiral pipe to the measured length and attach the sleeve. Standard Spiral Pipe Connector Pipe to Pipe connections are made by using a fitting size

    Get Price
  • Pipe Fitters Handbook

    2013-2-13u2002·u20026 ANVIL® PIPE FITTERS HANDBOOK GRUVLOK® INSTALLATION AND ASSEMBLY Figures 7400 & 7401 Couplings 1. Check & Lubricate Gasket Check gasket to be sure it is compatible for the intended service. Apply a thin coating

    Get Price
  • ASME B31.3 Process Piping Guide - Los Alamos National ...

    2009-4-1u2002·u2002LANL Engineering Standards Manual PD342 Chapter 17 Pressure Safety Section D20-B31.3-G, ASME B31.3 Process Piping Guide Rev. 2, 3/10/09 4 The Owner and Designer are responsible for compliance with the personnel and process qualification requirements of the codes and standards. In particular, the application of ASME B31.3 requires compliance with the …

    Get Price
  • Engineering & Piping Design Guide - NOV Inc.

    2019-10-8u2002·u20020.001 0.01 0.1 Pressure Loss - psig per 100 Feet of Pipe 10 11 01 00 1,000 10,0001 00,000 Flow Rate (gpm) - Gallons per Minute Fiberglass Pipe Pressure Loss Curves for Water

    Get Price
  • standards for industrial duct construction

    2021-6-19u2002·u2002Using Table 3, we realize that there is no tabulated gage for the exact data of the given example. The two data conditions bounding the given data for which there is a tabulated answer are: D = 36 in., Class 2, C = 50 pcf, L = 20 ft for which 18 gage is required. D = 36 in., Class 2, C = 75 pcf, L = 25 ft for which 14 gage is required.

    Get Price
  • SHEET METAL CATALOG - Excelsior

    2016-6-25u2002·u2002Galvanized Pipe, Round and Oval 14' Pipe 16' Pipe 18' Pipe 20' Pipe 24' Pipe 12' Pipe 10' Pipe 9' Pipe Length Gauge Item# 2' 24 140209 2' 26 130209 2' 28 120209 5' 24 140509 5' 26 130509 5' 28 120509 10' 28 120519 Length Gauge Item# 2' 24 140210 2' 26 130210 2' 28 120210 5' 24 140510 5' 26 130510 5' 28 120510 10' 28 120511 Length Gauge Item# 2 ...

    Get Price
  • Chapter 5 DESIGN STANDARDS AND SPECIFICATIONS

    2017-7-25u2002·u20025. DESIGN STANDARDS AND SPECIFICATIONS Design standards for this project will conform with 'Manual of Standard & Specifications for two laning of State Highways : SP:73(IRC-2007)', 'Specification for Road and Bridge Work' by Government of India, MORTH and various relevant IRC Standards and BIS Standards. Also 'Geometric Design Standards

    Get Price
  • Engineering Design Guidelines - Recycled Water (Non ...

    2011-2-3u2002·u2002Headloss for pipes less than 16 inches in diameter shall not be greater than 10 ft/1000 ft (4.2 psig per 1000 feet). Headloss for pipes equal to or greater than 16 inches diameter shall not be greater than 5 ft/1000 ft (2.2 psig). The Hazen & Williams formula with the coefficient of friction 'c'= 110 for all pipe

    Get Price
  • Performance Pipe

    2021-9-22u2002·u2002Performance Pipe — a division of Chevron Phillips Chemical Company LP — is the largest producer of polyethylene piping products in North America, with more than 40 years of proven performance, quality and innovation in natural gas, industrial, municipal, mining, oilfield and utility applications.

    Get Price
  • Pipe Bedding and Backfill

    2015-12-14u2002·u2002pipe. the pipe walls will not have to be designed as strong as for a line load. The backfill load is normally well distributed over the top of the pipe. However, proper pipe support must be constructed on the bottom of the pipe to distribute the load. Proper soil support under the bottom of the pipe is also necessary to maintain grade

    Get Price
  • Engineering & Piping Design Guide - NOV Inc.

    2019-10-8u2002·u20020.001 0.01 0.1 Pressure Loss - psig per 100 Feet of Pipe 10 11 01 00 1,000 10,0001 00,000 Flow Rate (gpm) - Gallons per Minute Fiberglass Pipe Pressure Loss Curves for Water

    Get Price
  • Structural Steel Connections, Joints Details

    2012-7-20u2002·u20026000. STEEL 6100& • 6130 ‐Design Data, Principles and Tools 6200 • 6140 ‐Codes and Standards • 6200 ‐Material 6300 • 6310 ‐Members and Components • 6320 ‐Connections, Joints and Details

    Get Price
  • SHEET METAL CATALOG - Excelsior

    2016-6-25u2002·u2002Galvanized Pipe, Round and Oval 14' Pipe 16' Pipe 18' Pipe 20' Pipe 24' Pipe 12' Pipe 10' Pipe 9' Pipe Length Gauge Item# 2' 24 140209 2' 26 130209 2' 28 120209 5' 24 140509 5' 26 130509 5' 28 120509 10' 28 120519 Length Gauge Item# 2' 24 140210 2' 26 130210 2' 28 120210 5' 24 140510 5' 26 130510 5' 28 120510 10' 28 120511 Length Gauge Item# 2 ...

    Get Price
  • standards for industrial duct construction

    2021-6-19u2002·u2002Using Table 3, we realize that there is no tabulated gage for the exact data of the given example. The two data conditions bounding the given data for which there is a tabulated answer are: D = 36 in., Class 2, C = 50 pcf, L = 20 ft for which 18 gage is required. D = 36 in., Class 2, C = 75 pcf, L = 25 ft for which 14 gage is required.

    Get Price
  • Chapter 5 DESIGN STANDARDS AND SPECIFICATIONS

    2017-7-25u2002·u20025. DESIGN STANDARDS AND SPECIFICATIONS Design standards for this project will conform with 'Manual of Standard & Specifications for two laning of State Highways : SP:73(IRC-2007)', 'Specification for Road and Bridge Work' by Government of India, MORTH and various relevant IRC Standards and BIS Standards. Also 'Geometric Design Standards

    Get Price
  • Metallic Piping Fabrication and Installation Method ...

    This method statement covers the sequence of activities for fabrication, erection and installation procedure for Metallic Piping. The method is useful for carbon steels, alloy steels, stainless steels and nickel alloys systems. Procedure will help to ensure the compliance of piping works with the contractual applications and HSE requirements.

    Get Price
  • Introduction to Tensile Testing - ASM International

    2013-11-24u2002·u2002Introduction to Tensile Testing 5 Fig. 6 The low-strain region of the stress-strain curve for a ductile material tic contribution and e e is the elastic contribution (and still related to the stress by Eq 3). It is tempting to define an elastic limit …

    Get Price
  • Pipe Bedding and Backfill

    2015-12-14u2002·u2002pipe. the pipe walls will not have to be designed as strong as for a line load. The backfill load is normally well distributed over the top of the pipe. However, proper pipe support must be constructed on the bottom of the pipe to distribute the load. Proper soil support under the bottom of the pipe is also necessary to maintain grade

    Get Price
  • Pipe Chart

    2021-9-24u2002·u2002Pipe dimension chart (11×17) Click to Print Our Pipe Dimension Chart. ANSI Pipe Chart. Use our ANSI Pipe Chart to determine the nominal pipe size, wall thickness, weight and schedule designations. For easy reference, print out this up-to-date chart. Click to Print Our Line Sheet. Pipe Chart Spreadsheet – Average Wall Thickness

    Get Price
  • Underground Installation of PE Piping - plastic pipe

    lateral pipe deformation. To ensure such support is available, this zone should extend from trench grade up to at least 75 percent of the pipe diameter. Under some conditions, such as when the pipe will be permanently below the ground water table, the primary initial backfill should extend to at least 6 inches over the pipe. 5 Figure 1 Pipe Trench

    Get Price
  • Guidelines for installation of integrally reinforced ...

    2015-6-27u2002·u2002specifications and meet the acceptance criteria therein. 6.2. The fitting to run pipe weld profile should meet the profiles as depicted in figures 1 through 3. 6.3. The fitting to run pipe weld size shall be considered adequate if the weld is filled out to the edge of fitting weld bevel. Some branch fittings possess

    Get Price
  • standards for industrial duct construction

    2021-6-19u2002·u2002Using Table 3, we realize that there is no tabulated gage for the exact data of the given example. The two data conditions bounding the given data for which there is a tabulated answer are: D = 36 in., Class 2, C = 50 pcf, L = 20 ft for which 18 gage is required. D = 36 in., Class 2, C = 75 pcf, L = 25 ft for which 14 gage is required.

    Get Price
  • Chapter 5 DESIGN STANDARDS AND SPECIFICATIONS

    2017-7-25u2002·u20025. DESIGN STANDARDS AND SPECIFICATIONS Design standards for this project will conform with 'Manual of Standard & Specifications for two laning of State Highways : SP:73(IRC-2007)', 'Specification for Road and Bridge Work' by Government of India, MORTH and various relevant IRC Standards and BIS Standards. Also 'Geometric Design Standards

    Get Price
  • PIPING ISOMETRICS - HCC Learning Web

    2015-10-3u2002·u2002• If the pipe's vertical, the lettering should be written vertically and at 30° angle • Dimensions appear to be lying down if the pipe is horizontal or standing on end if the pipe is vertical. • If pipe is in horizontal plane, the lettering will appear as if it is lying down and will be oriented on both 30° angles

    Get Price
  • Steel Structures Design Manual to AS 4100 V1

    2011-6-20u2002·u20027.1.3 Lateral Torsional Buckling 108 7.2 Design of Flexural Members to AS 4100 109 ... 7.3.11 Steel beam complete design check 131 7.3.12 Checking an I-section with unequal flanges 136 7.4 References 140 ... No attempt has been made to cover every topic of steel design in …

    Get Price
  • Pipeline Introduction

    Transportation of liquids by pipelines has been used for thousands of years. The first major exploitation and commercialization using pipelines started 150 years ago, and the building of long distance, large diameter pipelines was pioneered in the 1940's (Hopkins, 2007).Today's pipeline industry has originated from the oil business that brought considerable amount of profit to the energy ...

    Get Price
  • Introduction to Tensile Testing - ASM International

    2013-11-24u2002·u2002Introduction to Tensile Testing 5 Fig. 6 The low-strain region of the stress-strain curve for a ductile material tic contribution and e e is the elastic contribution (and still related to the stress by Eq 3). It is tempting to define an elastic limit as the stress at which plastic deformation first occurs

    Get Price
  • Guidelines for installation of integrally reinforced ...

    2015-6-27u2002·u2002specifications and meet the acceptance criteria therein. 6.2. The fitting to run pipe weld profile should meet the profiles as depicted in figures 1 through 3. 6.3. The fitting to run pipe weld size shall be considered adequate if the weld is filled out to the edge of fitting weld bevel. Some branch fittings possess

    Get Price
  • Pipe Chart

    2021-9-24u2002·u2002Pipe dimension chart (11×17) Click to Print Our Pipe Dimension Chart. ANSI Pipe Chart. Use our ANSI Pipe Chart to determine the nominal pipe size, wall thickness, weight and schedule designations. For easy reference, print out this up-to-date chart. Click to Print Our Line Sheet. Pipe Chart Spreadsheet – Average Wall Thickness

    Get Price
  • Chapter 5 DESIGN STANDARDS AND SPECIFICATIONS

    2017-7-25u2002·u20025. DESIGN STANDARDS AND SPECIFICATIONS Design standards for this project will conform with 'Manual of Standard & Specifications for two laning of State Highways : SP:73(IRC-2007)', 'Specification for Road and Bridge Work' by Government of India, MORTH and various relevant IRC Standards and BIS Standards. Also 'Geometric Design Standards

    Get Price
  • PIPING ISOMETRICS - HCC Learning Web

    2015-10-3u2002·u2002• If the pipe's vertical, the lettering should be written vertically and at 30° angle • Dimensions appear to be lying down if the pipe is horizontal or standing on end if the pipe is vertical. • If pipe is in horizontal plane, the lettering will appear as if it is lying down and will be oriented on both 30° angles

    Get Price
  • Reinforced Concrete Pipe

    Reinforced Concrete Pipe. Rinker Materials manufactures a complete line of standard and specially designed Reinforced Concrete Pipe for various applications. Tongue and. Groove Pipe…

    Get Price
  • Pipeline Introduction

    Introduction. Transportation of liquids by pipelines has been used for thousands of years. The first major exploitation and commercialization using pipelines started 150 years ago, and the building of long distance, large diameter pipelines was pioneered in the 1940's (Hopkins, 2007). Today's pipeline industry has originated from the oil ...

    Get Price
  • A324 WP11 elbow, Elbows ASTM A324 WPB - Alloy Pipe,

    ANSI B16. 9 Elbow A234 WP11 is the free machining version of this grade, accessible in a bar shape for utilizing in automatic screw machines. A324 WP11 elbow is the manufacturing process of ASTM A234 WPB. W = WELDABLE wrought. P = RELATED TO P NUMBER OF ALLOY MATERIAL. B = REFER TO MINIMUM YIELD OF MATERIAL.

    Get Price
  • GENERAL RUBBER LINING PRINCIPLES

    2021-1-23u2002·u2002vi. guidelines for number of laps in pipe and fittings blair rubber company section 13: rubber lining general rubber lining principles 5 section 13: rubber lining pipe size no. of max. longitudinal seams no. of circumferential seams 3' - 6' 1 1 in 14' to 10' sections 8' - 16' 2 (180° apart) 2 in 20' sections 0 in 8' and under ...

    Get Price
  • Self-standing Geodesic Family Tent Basic unit

    2019-6-18u2002·u2002IFRC/ICRC – Self-standing Geodesic Family Tent – Basic unit - specification 2019-04-16 page 4/50 1.3 Specifications for the pipe sleeves material Type and norms Required minimum values 1. Material ISO1833, colour Polyester canvas, red or blue. 2. Weight ISO3801 125g/m² +/-20% 160g +/- 50g 3. Tear strength ISO13937-2 Minimum 50N 4.

    Get Price
  • Design and Construction of Flagpoles

    2010-7-17u2002·u2002design meets the specification2. The flagpole specification uses ASCE 7 appears in the American Civil Engineer's Handbook5. It is strictly an empirical formula and was arrived at through some wind tunnel testing at the Naval Yard in Washington, D.C. According to this formula Force exerted by flag: F = 0.0003*A*V1.9 F = pounds A = flag area in ft2

    Get Price
  • Pipe Chart

    2021-9-24u2002·u2002Pipe dimension chart (11×17) Click to Print Our Pipe Dimension Chart. ANSI Pipe Chart. Use our ANSI Pipe Chart to determine the nominal pipe size, wall thickness, weight and schedule designations. For easy reference, print out this up-to-date chart. Click to Print Our Line Sheet. Pipe Chart Spreadsheet – Average Wall Thickness

    Get Price
  • Guidelines for installation of integrally reinforced ...

    2015-6-27u2002·u2002specifications and meet the acceptance criteria therein. 6.2. The fitting to run pipe weld profile should meet the profiles as depicted in figures 1 through 3. 6.3. The fitting to run pipe weld size shall be considered adequate if the weld is filled out to the edge of fitting weld bevel. Some branch fittings possess

    Get Price
  • Chapter 5 DESIGN STANDARDS AND SPECIFICATIONS

    2017-7-25u2002·u20025. DESIGN STANDARDS AND SPECIFICATIONS Design standards for this project will conform with 'Manual of Standard & Specifications for two laning of State Highways : SP:73(IRC-2007)', 'Specification for Road and Bridge Work' by Government of India, MORTH and various relevant IRC Standards and BIS Standards. Also 'Geometric Design Standards

    Get Price
  • WELDOLET SOCKOLET THREDOLET FLEXOLET LATROLET

    2017-7-13u2002·u2002• Mixed pipe schedules and dissimilar metals 36 - 22 (XS) X 4 (STD) FLEXOLET® A105N Please specify 1. Header (run) pipe size Header pipe is the pipe Olet® is welded onto 2. Branch pipe size Branch pipe is the outlet size that connects to Olet® 3. Style of branch connection Weldolet®, hredolet®, Sockolet®, Latrolet®, etc. 4.

    Get Price
  • Design and Construction Standards - Edmonton

    Table 11.38: Pipe Casing Spacers .....114 List of Figures Figure 1.1 Areas in Edmonton where water mains are generally considered to have a greater risk of freezing due to soil

    Get Price
  • SECTION 11100 - DESIGN STANDARDS FOR SANITARY

    2009-5-5u2002·u2002(SEE STANDARD TECHNICAL SPECIFICATIONS AND 10 STATE STANDARDS FOR COMPLETE REQUIREMENTS) DESIGN CAPACITY Average Flow 400 GPD/Single Family Dwelling_____ Peak Factor 1 to 248 ERU's - 4.0 250 to 499 ERU's - 3.75 500 to 1,999 ERU's - 3.5 2,000 to 7,499 ERU's - 3.0

    Get Price
  • SECTION 33 30 00 SANITARY SEWER UTILITIES PART 1 –

    B. Specification Section 33 31 20, Sewer Slip-Lining C. Specification Section 33 31 30, Pipe Bursting D. Specification Section 33 31 50, Bypass Pumping. E. Specification Section 33 39 13, Precast Concrete Manholes. F. Specification Section 33 39 17, Manhole Rehabilitation G. Specification Section 31 23 33, Trench Excavation and Backfill

    Get Price
  • SPECIFICATIONS - DETAILED PROVISIONS Section 03300

    Standard Specifications for Public work Construction Class 560-C-3250, 3250 psi concrete. Class 'A' 3,000 psi concrete or Class 560-C-3250 shall be provided for concrete used in: (i) all reinforced concrete, interior and exterior, not otherwise specified; (ii) anchors and anchor walls; (iii) pipe cradles, encasements, and beam supports;

    Get Price
  • Pipeline Introduction

    Transportation of liquids by pipelines has been used for thousands of years. The first major exploitation and commercialization using pipelines started 150 years ago, and the building of long distance, large diameter pipelines was pioneered in the 1940's (Hopkins, 2007).Today's pipeline industry has originated from the oil business that brought considerable amount of profit to the energy ...

    Get Price
  • CONCRETE ENCASED DUCT BANK - JEA

    SEAL-DUCT1 Seal duct pipe up to 6' diameter EA SEAL-DUCT2 Seal duct pipe up to 18' diameter EA SEAL-DUCT3 Seal duct pipe up to 36' diameter EA II.5.4. Overburden The following plates are designed for the replacement of the overburden in the removal, replacement and abandonment of concrete structures, to include backfill

    Get Price
  • STANDARD SPECIFICATIONS FOR CONSTRUCTION OF

    2021-5-19u2002·u2002STANDARD SPECIFICATIONS FOR CONSTRUCTION OF ROADS AND BRIDGES ON FEDERAL HIGHWAY PROJECTS FP-14 . U.S. …

    Get Price
  • PIPING ISOMETRICS - HCC Learning Web

    2015-10-3u2002·u2002• If the pipe's vertical, the lettering should be written vertically and at 30° angle • Dimensions appear to be lying down if the pipe is horizontal or standing on end if the pipe is vertical. • If pipe is in horizontal plane, the lettering will appear as if it is lying down and will be oriented on both 30° angles

    Get Price
  • STANDARD DETAILS - Honolulu

    2019-6-14u2002·u2002P-13 I Typical Horizontal Shaft Guard No. 1 • I I P-14 I Typical Horizontal Shaft Guard' No. 2 • ! P-15 Safety Guard General Notes • I P-16 1 ·1 /2' Stand Pipe Detail • ' i ' I I : 1 I i l I I ! i i I I I ' COUNTY OF KAUAI CITY & COUNTY OF HONOLULU CONTENTS STANDARD VII COUNTY OF MAUl DETAILS COUNTY OF HAWAII

    Get Price
  • The Horizontal Directional Drilling Process

    2015-8-6u2002·u2002drilling rig thus enlarging the pilot hole. Drill pipe is added behind the reamers as they progress toward the drill rig. This insures that a string of pipe is always maintained in the drilled hole. It is also possible to ream away from the drill rig. In this case, reamers fitted into the drill string at the rig are rotated and thrust away from it.

    Get Price
  • Chapter 9: Column Analysis and Design

    2015-2-20u2002·u2002Lateral translation is possible. • An eccentric column load is developed. Theoretical K-value: K = 2.0 Effective length: L e = 2.0 L P critical = π 2EI min /(2L) 2 = π2EI min /4L 2 Examples: Water tank mounted on a simple pipe column; flagpole. Case E: Both ends are fixed with some lateral translation. Theoretical K-value: K = 1.0 Effective ...

    Get Price
  • FILTER DESIGN EXAMPLE - suatiksu.org

    2014-3-17u2002·u2002Spacing of holes = L_lateral/no of holes per lateral = 19.5 cm. 0.061 6.13 cm XSS. area of lateral = 2 x area of perforations per lateral = 2 x 17.24 = 34.5 cm 2. 0.0063 m2 62.73 cm2 Diameter of lateral = (4 x 34 .5 p )1/2 = 6 .63 cm 0.0894 m 90.00 mm Choose a standard pipe diameter= 0.0900 m

    Get Price
  • Project Standards and Specifications

    2016-3-6u2002·u2002SPECIFICATIONS) Page 2 of 19 Rev: 01 July 2011 SCOPE This Project Standard and Specification specifies pressure and leak test procedure and acceptance criteria of piping works to perform minimum quality level. REFERENCES Throughout this Standard the following dated and undated standards/codes are referred to.

    Get Price
  • Painting of Piping and Equipments » The Piping

    2021-9-22u2002·u2002High quality painting of piping and equipments as well as structures, is essential to avoid corrosion. It helps ensure long life of a constructed plant and low maintenance costs. Painting involves not only total surface cover but also markings of various types such as line numbers, fluid codes, flow arrows, equipment numbers etc. Painting specification for […]

    Get Price
  • CONCRETE ENCASED DUCT BANK - JEA

    SEAL-DUCT1 Seal duct pipe up to 6' diameter EA SEAL-DUCT2 Seal duct pipe up to 18' diameter EA SEAL-DUCT3 Seal duct pipe up to 36' diameter EA II.5.4. Overburden The following plates are designed for the replacement of the overburden in the removal, replacement and abandonment of concrete structures, to include backfill

    Get Price
  • SECTION 11100 - DESIGN STANDARDS FOR SANITARY

    2009-5-5u2002·u2002(SEE STANDARD TECHNICAL SPECIFICATIONS AND 10 STATE STANDARDS FOR COMPLETE REQUIREMENTS) DESIGN CAPACITY Average Flow 400 GPD/Single Family Dwelling_____ Peak Factor 1 to 248 ERU's - 4.0 250 to 499 ERU's - 3.75 500 to 1,999 ERU's - 3.5 2,000 to 7,499 ERU's - 3.0

    Get Price